Chapter 3 Preparing for Universal Replicator z/OS Operations

Hitachi Universal Replicator for IBM /OS User’s Guide

15:00

14:00

13:00

12:00

15:02

14:02

13:02

12:02

15:03

14:03

13:03

12:03

15:04

14:04

13:04

12:04

Journal group 1

Extended consistency group

Journal group 2

Journal group 3

Journal group 4

indicates data that is to be restored to secondary data volumes

Legend:

indicates data that is not to be restored to secondary data volumes

Figure 2-4

Time Stamps of Data that Have Not Been Restored to
Secondary Data Volumes

Consistency time:

In the URz windows, consistency times of extended consistency groups,

journal groups, and data volume pairs are displayed. These consistency

times have the following meanings.

The consistency time of an extended consistency group is the latest
time stamp of the restored data in the group in which consistency is

guaranteed.
In the example shown in Figure 2-4, the consistency time of the

extended consistency group is 15:00.

The consistency time of a journal group is the latest time stamp of the
restored data.
In the example shown in Figure 2-4, the consistency times of journal

groups 1 to 4 are as follows.
• The consistency time of Journal group 1 is 15:00.
• The consistency time of Journal group 2 is 14:02.
• The consistency time of Journal group 3 is 14:03.
• The consistency time of Journal group 4 is 14:04.

The consistency time of a data volume pair is the latest time stamp of
the data that has been restored when the pair becomes suspended.
In the example shown in Figure 2-4, if a pair in the journal group 1, 2,

3 or 4 is suspended immediately after data are restored, the

consistency time of the pair will be as follows.
• If a pair in Journal group 1 is suspended, the consistency time will

be 15:00.

• If a pair in Journal group 2 is suspended, the consistency time will

be 14:02.

• If a pair in Journal group 3 is suspended, the consistency time will

be 14:03.