Other parameters, Iapp parameters, Spectralink voip parameters (802.11b only) – HP ProCurve 520wl Wireless Access Point User Manual

Page 181: Command line interface (cli) other parameters, C-45

Advertising
background image

Command Line Interface (CLI)

Other Parameters

IAPP Parameters

Name

Type

Values

Access CLI Parameter

IAPP

Group

N/A

R

iapp

IAPP Status

Integer

enable (default)
disable

RW

iappstatus

Periodic Announce
Interval (seconds)

Integer

80
120 (default)
160
200

RW

iappannint

Announce Response
Time

Integer

2 seconds

R

iappannresp

Handover Time-out

Integer

410 ms
512 ms (default)
614 ms
717 ms
819 ms

RW

iapphandtout

Max. Handover
Retransmissions

Integer

1 - 4 (default 4)

RW

iapphandretx

Send Announce
Request on Startup

Integer

enable (default)
disable

RW

iappannreqstart

NOTE�

These parameters configure the Inter Access Point Protocol (IAPP) for roaming. Leave these settings at their
default value unless a technical representative asks you to change them.

SpectraLink VoIP Parameters (802.11b Only)

Name

Type

Values

Access CLI Parameter

Spectralink VoIP

Group

N/A

R

spectralink

Spectralink VoIP Status

Integer

enable
disable (default)

RW

speclinkstatus