background image

Advanced Configuration

Image Alarms

Trap Name

Description

oriTrapZeroSizeImage

This trap is generated when a zero size image is loaded on the AP.
Trap Severity Level: Major

oriTrapInvalidImage

This trap is generated when an invalid image is loaded in the Access Point.
Trap Severity Level: Major

oriTrapImageTooLarge

This trap is generated when the image loaded in the AP exceeds the size
limitation of the flash memory.
Trap Severity Level: Major

oriTrapIncompatibleImage

This trap is generated when an incompatible image is loaded in the AP.
Trap Severity Level: Major

In addition, the AP supports these standard traps, which are always enabled:
RFC 1215-Trap

Trap Name

Description

coldStart

The AP has been turned on or rebooted.
Trap Severity Level: Informational

linkUp

The AP's Ethernet interface link is up (working).
Trap Severity Level: Informational

linkDown

The AP's Ethernet interface link is down (not working).
Trap Severity Level: Informational

Bridge MIB (RFC 1493) Alarms

Trap Name

Description

newRoot

This trap indicates that the AP has become the new root in the Spanning Tree
network.
Trap Severity Level: Informational

topologyChange

This trap is sent by the AP when any of its configured ports transitions from the
Learning state to the Forwarding state, or from the Forwarding state to the
Blocking state.
This trap is not sent if a newRoot trap is sent for the same transition.
Trap Severity Level: Informational

All these alarm groups correspond to System Alarms that are displayed in the

System Status

screen, including the

traps that are sent by the AP to the SNMP managers specified in the

Alarm Host Table

.

Severity Levels

There are three severity levels for system alarms:

Critical

Major

Informational

Critical alarms will often result in severe disruption in network activity or an automatic reboot of the AP.
Major alarms are usually activated due to a breach in the security of the system. Clients cannot be authenticated or an
attempt at unauthorized access into the AP has been detected.
Informational alarms are there to provide the network administrator with some general information about the activities
the AP is performing.

4-30