Table 7 RAID Manager Error Codes (continued)

Description

SSB2 code

The Quick Restore or reverse copy operation was rejected because the volume you specified as the
volume was specified as the P-VOL for XRC.

23A8

The Quick Restore or reverse copy operation was rejected because the volume you specified as the
volume was specified as the P-VOL for CC.

23A9

The pair operation was rejected because the volume you specified as the S-VOL was specified as the
P-VOL for XRC.

23AA

The pair operation was rejected because the volume you specified as the S-VOL was specified as the
P-VOL for CC.

23AB

Registering the pair in the consistency group from RAID Manager was rejected because the consistency
group number you specified was reserved by PPRC/BCM.

23AF

The create pair was rejected because the volume you specified as the S-VOL could not be used as
the S-VOL because of Volume Security settings.

23BB

The pair deletion was rejected because the source and target volumes were being Quick Split.

23EF

The pair operation was rejected because the split time for the consistency group was set.

23F5

The Add Pair operation was rejected because the CTGID you specified was not supported.

23F1

You cannot execute the command because the system could not authenticate the user.

9100

The pair operation was rejected because the volume you specified did not exist.

B911

The pair operation was rejected because the S-VOL specified at the pair operation did not exist.

B912

The pair operation was rejected because the mirror ID was invalid.

B913

Troubleshooting the At-Time Split

If the At-Time Split fails, note the following:

The pairs in the consistency group are suspended (Suspend/SUSPER statis).

When the host server is down or has failed, you can define a consistency group that does not
have BC Z pairs. Running the paircreate command with the consistency group split option
under such a condition can cause the paircreate command to be rejected.

In this case, complete the following:
1.

Locate a consistency group number that is not used by any pairs in the Pair Operation
window by sorting the CTG column.

2.

Specify that consistency group number explicitly, and run the paircreate command
with the consistency group split option using RAID Manager on the host server.

When you use a Cnt Ac-J Z S-VOL as a BC Z P-VOL and you cannot change the status of some
pairs in a consistency group, some pairs remain unsplit in the consistency group after you run
the pairsplit command in RAID Manager. Consistency is not guaranteed.

The following are possible reasons why the pair status cannot be changed:

The Cnt Ac-J pair belongs to a consistency group, and the P-VOL and S-VOL have the
same contents. The journal volumes for this pair are full.

The BC Z license is invalid.

The BC Z pair volumes are blocked.

Troubleshooting with RAID Manager

65