Add dkc dialog box – HP XP P9500 Storage User Manual

Page 180

Advertising
background image

Description

Item

Communication Time Out. This status indicates one of the following:

A timeout error has occurred between the primary and the secondary systems.

A logic error is detected between the primary and the secondary systems.

Port Rejected. The local system rejected configuration of the logical path connection. Logical
path resources in the local system might be in use for other connections.

Pair Port Rejected. The remote system rejected configuration of the logical path connection.
Logical path resources in the remote system might be in use for other connections.

Serial Number Mismatch. The serial number of the system connected to this logical path
does not match the serial number specified by the Add DKC dialog box.

Invalid Port Mode. The port is not an initiator port.

Pair-Port Number Mismatch. Indicates one of the following:

The specified port number is incorrect.

The port in the remote system is physically disconnected from the local system.

Pair-Port Type Mismatch. The port on the remote system is not an RCU target port.

Communication Failed. A communication timeout error has occurred on the path between
the local and remote systems.

The port on the local system.

Port

The port on the remote system.

Pair-Port

The serial number and LDKC number of the remote system.

S/N

The controller ID and model name (in parenthesis) for the remote system.

Controller ID

The path group ID

Path Gr. ID

The type of channel interface between local and remote systems. Always displays column
displays “Fibre”.

M-R Path

The minimum possible number of paths between the local and the remote systems.

Minimum Paths

The remote I/O missing interrupt handler timer value—the wait time for data transfer from the
local to remote system to complete.

RIO MIH

The date and time when local and remote systems were associated to each other

DKC Registered

The date and time the last operation on a logical path to the remote system was performed.

Last Updated

When clicked, the DKC Operation window refreshes when it re-displays.

Refresh the DKC
Operation tab after
this panel is closed

Add DKC dialog box

Use this dialog box to configure local and remote systems for Continuous Access Journal pairs.
See

“Configuring local and remote systems for Cnt Ac-J ” (page 45)

for complete information.

180 GUI reference

Advertising