HP XP P9500 Storage User Manual

Page 67

Advertising
background image

S-VOL access

P-VOL
access

Description

RAID Manager status

RWC status

Read Only

Read/Write

4

The pair is synchronized. Updates to the P-VOL are
duplicated on the S-VOL.

PAIR

PAIR

Read Only

Read/Write

4

If data in the journal volume exceeds the threshold (80 %),
pair status changes to PFUL. The pair is not suspended; the
copy operation continues.

PFUL

RWC
displays this
status as PAIR

If the journal option, Inflow Control, is set to Yes when status
changes to PFUL, host I/O is delayed because update I/O
to the journal volume is delayed.

Read Only,
unless write

Read/Write

4

The pair has been split by the user and the P-VOL and S-VOL
are no longer synchronized.

SSUS

PSUS

option is
enabled.

•

The primary and secondary systems keep track of journal
data discarded during the split operation.

•

When the operation is performed on the primary system,
the status of both the P-VOL and S-VOL changes to PSUS.

•

When the operation is performed on the secondary
system, the status of the S-VOL changes to PSUS; the
primary system detects this and changes P-VOL status to
PSUS.

SSUS is the S-VOL’s split status name.

See also

“PSUS types and behaviors” (page 69)

.

Read Only

RWC:
Read/Write

4

The pair is suspended by the system due to an error; it is
not synchronized.

PSUE

PSUE

RAID

•

The primary and secondary systems keep track of journal
data discarded during the suspension operation.

Manager:
Read/Write

4

•

The primary system keeps track of P-VOL tracks that are
updated while the pair is suspended.

if no error
in P-VOL

•

When a Cnt Ac-J suspension condition is detected, the
primary system changes P-VOL and S-VOL status to PSUE.
If the secondary system detects the condition, it changes
the S-VOL status to PSUE; the primary system detects this
and changes P-VOL status to PSUE.

See also

“PSUS types and behaviors” (page 69)

.

Read Only

Read/Write

4

The pair is not synchronized and in transition from the PAIR
or COPY status to PSUS or PSUE status.

(No parallel RAID
Manager status)

Suspending

Read Only

Read/Write

4

The pair relationship is being deleted. When the operation
completes, status changes to SMPL.

(No parallel RAID
Manager status)

Deleting
(releasing)

Read Only

2

Read/Write

1

(No parallel RAID
Manager status)

HOLD

•

The pair or command devices are ready for the delta
resync operation. Incoming write data for the Cnt Ac-S
S-VOL is stored in the master journal volume.

•

Operations allowed:

- Delta resync

- Pair-delete

- Change pair options

-

Read/Write

1

Pair status is changing to HOLD so that the delta resync pair
can be created.

(No parallel RAID
Manager status)

HOLDING

3

Operations allowed on pairs in HOLDING status:

•

Delta resync operation

•

Pair release

•

Change pair options

Monitoring pair activity and status

67