Raid manager mirror status definitions, Monitoring logical path status – HP XP P9500 Storage User Manual

Page 78

Advertising
background image

Description

Status

An operation for splitting or deleting the mirror is finished.

Stopped

A Cnt Ac-J delta resync pair has been created. It is ready for the delta resync operation.

Hold

A Cnt Ac-J delta resync pair is being created.

Holding

An error occurred with the Cnt Ac-J pair during the delta resync operation.

Hold(Failure)

This is an unused journal.

Blank

RAID Manager mirror status definitions

RAID Manager mirror statuses appear beside Remote Web Console statuses in the RWC/RAID
Manager format. The following describe RAID Manager statuses.

Description

Status

The mirror is not used.

SMPL

The primary journal is normal.

PJNN

The secondary journal is normal.

SJNN:

The primary journal is in normal split status.

PJSN

The secondary journal is in normal split status.

SJSN

The primary journal is in normal split status (Delta resync configuration).

PJNS

The secondary journal is in normal split status (Delta resync configuration).

SJNS

The primary journal is full.

PJNF

The secondary journal is full.

SJNF

The primary journal is full and split.

PJSF

The secondary journal is full and split.

SJSF

The primary journal is split due to an error (including link errors).

PJSE

The secondary journal is split due to an error (including link errors).

SJSE

The primary journal is in split status (Delta resync configuration) due to an error.

PJSE

The secondary journal is in split status (Delta resync configuration) due to an error.

SJSE

Monitoring logical path status

To view logical path status
1.

In the Remote Web Console main window, select Actions > Remote Copy > Continuous Access
Journal > DKC Operation.

2.

In the Display box, select DKC and select LDKC.

3.

Locate the remote system in the list on the right side and view the Status column.

4.

To see in-depth path status, right-click the remote system and select DKC Status.

Description

Item

Number of the row.

No

Status of a logical path. For status definitions and troubleshooting, see

“Troubleshooting logical

paths ” (page 105)

.

Path Status

Port on the local system.

Port

78

Monitoring the system

Advertising