Deleting journals, Logical path maintenance, Modifying data-transfer time threshold – HP XP P9500 Storage User Manual

Page 86

Advertising
background image

9.

Click Apply to apply the settings. If an error occurs, right click the item in the Preview list and
select Error Detail.

Deleting journals

Journals can be deleted from either system.

Prerequisite information

Journals can be deleted from the primary or secondary system.

All mirrors in the journal must be Initial status.

Master and restore journals cannot be deleted.

Procedure 22 To delete a journal

1.

In the Remote Web Console main window, select Actions > Remote Copy > Continuous Access
Journal > Journal Operation. The Journal Operation window displays.

2.

Click

to change the mode from View to Modify.

3.

From the tree, click Registered > LDKC00. Journals display in the list on the right.

4.

Select and right-click the desired journal. Only one journal can be selected. Click Journals >
Delete JNL from the menu that displays.

5.

Review your settings in the Preview list in the Journal Operation window.

To modify a setting, right click and select Modify.

To cancel a setting, right click and select Cancel.

6.

Click Apply to apply the settings. If an error occurs, right click the item in the Preview list and
select Error Detail.

Logical path maintenance

This topic provides the following:

Modifying data-transfer time threshold

“Deleting logical paths ” (page 87)

“Deleting the Cnt Ac-J relationship ” (page 87)

Modifying data-transfer time threshold

You can modify the threshold for data transfer to complete. If the threshold value is reached, the
transfer is flagged as failing by the system.

Prerequisite information

This operation can be performed from the primary or secondary system.

The setting is made in the RIO MIH field on the DKC Options dialog box (RIO MIH--remote
I/O missing interrupt handler).

Procedure 23 To change the data-transfer threshold time

1.

In the Remote Web Console main window, select Actions > Remote Copy > Continuous Access
Journal > DKC Operation. The DKC Operation window displays.

2.

Click

to change the mode from View to Modify.

3.

Make sure DKC is selected in the Display box. The tree and full list on the right-side display
information about the paired secondary systems

4.

Locate the desired remote system, right-click, and select DKC Operation > Change DKC Option.
The DKC Option dialog box displays.

5.

Minimum Paths is disabled in this release. Please continue.

86

Maintaining the system