Pair status descriptions – HP XP P9500 Storage User Manual

Page 37

Advertising
background image

Figure 9 ESAM pair status transitions

1.

If a volume is not assigned to an ESAM pair, its status is SMPL.

2.

Create an ESAM pair using SMPL volumes. During copy processing, the status of the P-VOL
and the S-VOL changes to COPY.

3.

The status of the P-VOL and the S-VOL changes to PAIR when copy processing completes.

4.

If you split the pair, the status of the P-VOL and the S-VOL changes to PSUS (pair suspended-split,
split by command).

5.

When the MCU cannot keep the P-VOL and the S-VOL synchronized due to an error condition,
the status of the P-VOL and the S-VOL changes to PSUE (pair suspended-error, split due to an
error). If the MCU cannot communicate with the RCU, the status of the S-VOL stays PAIR.

6.

If a failover occurs in the storage system, the status of the S-VOL changes to SSWS, and the
status of the P-VOL changes to PSUS.

7.

When you resynchronize the pair in PSUS or PSUE status (see No.4 and No.5), the status of
the P-VOL and the S-VOL changes to COPY.

8.

When you resynchronize the pair whose S-VOL is in SSWS status (see No.6), (using the RAID
Manager pairresync -swaps command on the S-VOL), the P-VOL and the S-VOL are
swapped and the pair status changes to COPY.

9.

When you release the pair, the status of the P-VOL and the S-VOL changes to SMPL.

Pair status descriptions

Status descriptions are provided in the following table. Click File/Refresh to make sure data is
current.

Table 5 Pair status descriptions

Access

Access

Description

Status

Monitoring pair status

37