You cannot change the remote command device setting. When the storage system setting is
output to the spreadsheet, the remote command device setting is commented out with #$ at
the beginning of the row.

In the spreadsheet, change the colons that usually separate the LDEV numbers for an LDEV to
commas.

For example:

[LDEV]

00,00,01,Disable,Disable,,,,,, 00,00,01,Enable,Enable
00,01,01,Disable,Disable,,,,,, 00,01,01,Enable,Disable
00,02,01,Disable,Disable,,,,,, 00,02,01,Enable,Disable
00,03,01,Disable,Disable,,,,,, 00,03,01,Enable,Disable

The following table lists the values for the [LDEV] function tag.

Available value

Item

Column

00

Ldkc

11th (Index)

00 - FE. Set with hexadecimal numbers in one or two digits.

Cu

12th (Index)

00 - FF. Set with hexadecimal numbers in one or two digits.

Ldev

13th (Index)

Enable or Disable (The default when the spreadsheet is exported)

Cmd. Dev

14th

ON or OFF are also available as the set value when you write the
spreadsheet.

(Command
Device)

Enable or Disable (The default when the spreadsheet is exported)

Cmd. Sec
(Command

15th

ON or OFF are also available as the set value when you write the
spreadsheet.

Device
Security)

Enable or Disable (The default when the spreadsheet is exported)

Cmd.Usr (User
Authentication)

16th

ON or OFF are also available as the set value when you write the
spreadsheet.

Enable or Disable (The default when the spreadsheet is exported)

Cmd.Grp
(Device Group
Definition)

17th

ON or OFF are also available as the set value when you write the
spreadsheet.

CAUTION:

When configuration definitions are long, the [LDEV] function tag might not appear

in the exported spreadsheet. In that case, add the [LDEV] function tag and set the command
device.

CAUTION:

The 18th column is used only for outputting information. Do not specify attributes in

this column. When changing settings, you must specify the 18th column as a blank.

Importing and validating CFL-based spreadsheets in LUN Manager

Use this procedure to import the spreadsheet back into CFL and validate it.

Importing CFL-based spreadsheets does the following:

Accepts the spreadsheet.

Verifies the formats of the function tags.

Validates the contents.

Compares the function tags in the current configuration definition area with the function tags
you added to the new configuration definition area. If errors are not detected, the spreadsheet
status changes to “Ready”. If errors are detected, the spreadsheet status changes to “Error”