Setting the number of trace files -85, Setting up audit log data collection -85 – HP XP Racks User Manual

Page 151

Advertising
background image

Setting the Number of Trace Files

You can set the number of the trace files.

Trace files for which the number of files can be set are hdlmtrn.log (n

indicates a file number from 1 to 64).

For the number of the trace files, you can specify a value from 2 to 64. If you

specify a value smaller than the value that has already been specified, the

KAPL01097-W message will be displayed to confirm the execution, and the

trace file will be temporarily deleted.

By specifying both the trace file size and the number of trace files, you can

collect up to 1024000KB of trace data.

The following is an example of setting up the number of trace files by using a

command:

# /usr/DynamicLinkManager/bin/dlnkmgr set -systfn 10

Specify the number of trace files by using numbers.

Setting Up Audit Log Data Collection

You can set whether to collect audit log data.

If you want to collect audit log data, you must also specify the collection level

for audit log data and the audit log categories.

The table below lists and describes the values for the audit log collection level

setting.

An audit log data collection level is a severity level. The default is 6.

Table 3-15 Values Indicating Audit Log Data Collection Levels

Value (severity)

Explanation

0

No audit log data is collected.

1

2

Critical-level audit log data is collected.

3

Critical-level and Error-level audit log data is collected.

4

Critical-level, Error-level, and Warning-level audit log data is

collected.

5

6

Critical-level, Error-level, Warning-level, and Informational-level

audit log data is collected.

7

The table below lists and describes the values for the audit log category

setting. The default is all.

Creating an HDLM Environment

3-85

Hitachi Dynamic Link Manager (for AIX) User Guide

Advertising
This manual is related to the following products: