HP XP Racks User Manual

Page 241

Advertising
background image

Intermittent error monitoring can be enabled only when automatic

failback is set to on.
When you use automatic failback, we recommend that you set

intermittent error monitoring to on to prevent an intermittent error from

reducing I/O performance.
If on is specified, be sure to also specify the intermittent error monitoring

interval and the number of times that the error is to occur. The system

assumes that an intermittent error is occurring if the specified number of

times that the error is to occur is reached during the monitoring interval.

A path that is assumed to have an intermittent error is excluded from

automatic failbacks. Intermittent error monitoring is performed on each

path. Intermittent error monitoring starts when a path is recovered from

an error by performing an automatic failback.
If you omit the intermittent error monitoring interval or the number of

times that the error is to occur, each setting is specified as follows:

¢

When the intermittent error monitoring interval or the number of

times that the error is to occur has not been specified before:
The intermittent error monitoring interval is set to 210 minutes, and

the number of times that the error is to occur is set to 3.

¢

When the intermittent error monitoring interval or the number of

times that the error is to occur has been specified before:
The values specified from the last time are used.

When a value of 2 or more is specified for the number of times, the

following condition must be satisfied:

error-monitoring-interval >= checking-interval-for-automatic-

failback × number-of-times-error-is-to-occur-during-intermittent-

error-monitoring

If this condition is not satisfied, the KAPL01080-W message will be output

and an error will occur. If this happens, change any of the following

settings: the checking interval for automatic failback, intermittent error

monitoring interval, or the number of times that the error is to occur.
When you set the number of times that the error is to occur to 1, the

above condition does not need to be satisfied.
The following shows the sub-parameters that should be specified: the

error monitoring interval and the number of times that the error is to

occur:

-intvl error-monitoring-interval

Specify the monitoring interval for an intermittent error. Use a value

from 1 to 1440 minutes. The default is 210.
During intermittent error monitoring, if changes are made to the

intermittent error monitoring interval setting or the setting for the

number of times that an error is to occur, the error count and the

elapsed time measured since monitoring has started are reset to 0.
When intermittent error monitoring is not being performed, if changes

are made in the settings of the intermittent error monitoring interval

or the number of times that an error is to occur, the new settings will

take effect after the next time an automatic failback is successful.

Command Reference

6-25

Hitachi Dynamic Link Manager (for AIX) User Guide

Advertising
This manual is related to the following products: