Message

ID

Message Text

Explanation

If the error code is 6,2 or
7,-1:

The bosboot

command is not in the

default location, or the

user does not have

execution permissions

for the bosboot

command. Check the

status of the bosboot

command.

If the error code is 9,2 or
10,-1:

The dlmpr utility is not

in the default location,

or the user does not

have execution

permissions for the
dlmpr utility. Check

the status of the
dlmpr utility.

If the error code is 11,2 or
12,-1:

The mkdev command is

not in the default

location, or the user

does not have

execution permissions

for the mkdev

command. Check the

status of the mkdev

command.

Any other error code:

Contact your HDLM

vendor or the

maintenance

company, if you have

an HDLM maintenance

contract.

KAPL10585-

I

Reboot the host.

Details

Reboot the host to apply

the changes to the

settings.

Action

None.

KAPL10586-

I

Processing terminated before completion

because a signal was received.

Details

The dlmchpdattr process

has been terminated by an

operation such as Ctrl+C.

Action

Messages