HP XP Racks User Manual

Page 333

Advertising
background image

Key name

#1

Description

#2

Necessity of

definition

Maxim

um

numbe

r of

charac

ters

New

installa

tion

Upgrad

e

installa

tion or

re-

installa

tion

(rr), Least I/Os (lio), or Least

Blocks (lbk) algorithm is used for

load balancing.
You can specify a value from 0 to
999999. The default is 20.

lbex_usetimes_limi
t

Specify the number of times the

same path can be used for

sequential I/O operations when the

extended Round Robin (exrr),

Least I/Os (exlio), or Least Blocks

(exlbk) algorithm is used for

extended load balancing.
You can specify a value from 0 to
999999. The default is 100.

Optional Optional 6

error_log_level

Set the level of error information

that is collected as error logs.
You can set a level from 0 to 4. The

default is 3.

Optional Optional 1

error_log_size

Set the size of the error log files

(dlmmgr[1-16].log) in kilobytes.
You can set a size from 100 to
2000000. The default is 9900.

Optional Optional 7

error_log_number

Set the number of error log files

(dlmmgr[1-16].log).
You can set a value from 2 to 16.

The default is 2.

Optional Optional 2

trace_level

Set the trace output level.
You can set a level from 0 to 4. The

default is 0.

Optional Optional 1

trace_file_size

Set the size of the trace files

(hdlmtr[1-64].log) in kilobytes.
You can set a size from 100 to
16000. The default is 1000.

Optional Optional 5

trace_file_number

Set the number of trace files

(hdlmtr[1-64].log).
You can set a value from 2 to 64.

The default is 4.

Optional Optional 2

Utility Reference

7-39

Hitachi Dynamic Link Manager (for AIX) User Guide

Advertising