# rmpath -p fscsin -d

Because the fscsi number found in step 1 is 1 (fscsi1), the result is as

follows:

# rmpath -p fscsi1 -d

5

.

Execute the following command to get the name of the parent device:

# lsdev -C -l fscsin -F parent

6

.

Delete the HBA device associated with the Fibre Channel switch that is to

be replaced.

# rmdev -dl fscsin -R

7

.

Replace the Fibre Channel switch.

8

.

Execute the following command to reconfigure the HBA device:

# cfgmgr -l fcsn

fcsn indicates the name of the parent device that was acquired in step 5;
n indicates the instance number of the fcs device.

9

.

Execute the following command to check the path information:

# /usr/DynamicLinkManager/bin/dlnkmgr view -path

For details about path information, see

view (Displays Information) on

page 6-34

.