Changing the size of integrated trace files, Changing the size of integrated trace files -89 – HP XP Racks User Manual

Page 155

Advertising
background image

# /opt/hitachi/HNTRLib2/bin/hntr2utl2

The Hitachi Network Objectplaza Trace Library setup menu appears.

If you do not want to change the settings, type e and then press the

Enter key to quit the menu.
The following explains how to modify each setting.

Changing the Size of Integrated Trace Files

The following procedure shows how to change the size of integrated trace

files.

To change the size of integrated trace files:

1

.

In the Hitachi Network Objectplaza Trace Library setup menu, type 1 and

then press the Enter key.
A screen to set the size of the integrated trace file will appear. The

current value is displayed in Current Size (KB).

2

.

Enter the desired size in New Size (KB).
The specifiable range is between 8 KB and 8192 KB, with a default of 256.

Set this to a value larger than that set in step 2 of

Changing the Buffer

Size Per Monitoring Interval Duration on page 3-90

. We recommend

setting a value of 4096 when collecting an integrated trace.
If you do not want to change the integrated trace file size, leave New

Size (KB) blank, type !, and then press the Enter key to return to the

Hitachi Network Objectplaza Trace Library setup menu.

Creating an HDLM Environment

3-89

Hitachi Dynamic Link Manager (for AIX) User Guide

Advertising
This manual is related to the following products: