Host mode options

No.

When you do not want to generate the failover from MCU to RCU, and when
the applications that issue the Read commands more than the threshold to
S-VOL of the pair made with External Storage Access Manager are performed.

ESAM Svol Read Option

48

When you want to adjust the number of buffer-to-buffer credits (BBCs) to control
the transfer data size by the fibre channel, for example when the distance

BB Credit Set Up Option1

3

49

between MCU and RCU of the Continuous Access Synchronous pair is long
(approximately 100 kilometers) and the Point-to-Point topology is used.

Use the combination of this host mode option and the host mode option 50.

When you want to adjust the number of buffer-to-buffer credits (BBCs) to control
the transfer data size by the fibre channel, for example when the distance

BB Credit Set Up Option2

3

50

between MCU and RCU of the Continuous Access Synchronous pair is long
(approximately 100 kilometers) and the Point-to-Point topology is used.

Use the combination of this host mode option and the host mode option 49.

If you want to adjust the response time of the host I/O, for example when the
distance between MCU and RCU of the Continuous Access Synchronous pair
is long (approximately 100 kilometers).

Round Trip Set Up Option

3

51

Use the combination of this host mode option and the host mode option 65.

When a cluster software using the SCSI-2 reserve is used in the External
Storage Access Manager environment.

ESAM and Cluster software for
SCSI-2 Reserve

52

When the VAAI (vStorage API for Array Integration) function of VMware
ESX/ESXi 4.1 is used.

Support Option for the
EXTENDED COPY command

54

When you use 0C Windows, 2C Windows Extension, 01 VMware, or 21
VMware Extention as the host mode in the External Storage Access Manager
environment.

ESAM response change

57

When HP-UX 11.31 is used, and when you want to prevent adding or deleting
of LUN0.

LUN0 Change Guard

60

Use this Host Mode Option when 128 keys are insufficient for the host.

Expanded Persistent Reserve
Key

61

When you connect the storage system to VMware ESXi 5.0 and use the VAAI
function for T10.

Support Option for vStorage
APIs based on T10 standards

63

If you want to adjust the response time of the host I/O when you use the host
mode option 51 and the host connects the Continuous Access Synchronous

Round Trip extended set up
option

3

65

pair. For example, when the configuration using the maximum number of
processor blades is used.

Use the combination of this host mode option and the host mode option 51.

When the OPEN fibre channel port configuration applies to following:

Change of the ED_TOV value

67

The topology is the Fibre Channel direct connection.

The port type is Target or RCU Target.

Notes:

1.

Configure these host mode options only when requested to do so.

2.

Set the UUID when you set host mode option 33 and host mode 05 OpenVMS is used.

3.

Host mode options 49, 50, 51, and 65 are enabled only for the 8UFC/16UFC package.

Find WWN of the host bus adapter

Before physically attaching the storage system to hosts, some preparation work needs to be
performed. When configuring a fibre channel environment, first verify that the fibre adapters and
the fibre channel device drivers are installed on the open-system hosts. Next, find the World Wide
Name
(WWN) of the host bus adapter that is used in each open-system host.

Configuring hosts