Description

Item

of the CHF port as 8 Gbps. However, the transfer speed of the CHF port
cannot be set as 1 Gbps when the CHF is 8US. Therefore, 1-Gbps HBA
and switch cannot be connected. If the Auto Negotiation setting is required,
the linkup may become improper at server restart. Check a channel lamp,
and if it is blinking, remove and re-insert the cable to perform the signal
synchronization and linkup.

When the transfer speed of the CHF port is set to Auto, the data might not
be transferred at the maximum speed depending on the connected device.
Confirm the transfer speed appearing in Speed in the Ports list when you
start up the storage system, HBA, or switch. When the transfer speed is not
the maximum speed, select the maximum speed from the list on the right or
remove and reinsert the cable.

Only 10 Gbps can be specified for the FCoE port. Auto cannot be specified
for the FCoE port.

Select the address of the selected port.

Address (Loop ID)

Select whether a fabric switch is set to ON or OFF. Only ON can be specified
for the FCoE port.

Fabric

Select the topology.

Connection Type

FC-AL: Fibre channel arbitrated loop

P-to-P (point-to-point). Only P-to-P can be specified for the FCoE port.

Caution: Some fabric switches require that you specify point-to-point
topology. If you enable a fabric switch, check the documentation for the
fabric switch to determine whether your switch requires point-to-point
topology.

Confirm window

Confirm proposed settings, name the task, and then click Apply. The task will be added to the
execution queue.

370 LUN Manager GUI reference