Innovate Motorsports LogWorks 3 User Manual

Page 54

Advertising
background image

LogWorks3_Manual_1.01.doc

- 54 -

Unique application of Trigger Conditions


One convenient application for the Triggers, when using LogWorks plug-ins, is to use for example
OBDII data to start and stop logs without touching a laptop. For example if the position of the rear
window defogger switch (bit channel) is used, than you can use:

(Rear_Defogger > 0.5) as Start Condition and
(Rear_Defogger < 0.5) as Stop Condition.

Because Rear_defogger is a bit-channel that can only have the values 0 and 1, the start condition
is satisfied when you switch the rear defogger on. The stop condition is satisfied when the rear
defogger is off. So the defogger switch becomes a Record Button.





Advertising