5 - adjustments – MagTek EC2000 99875607 User Manual
Page 150

5 - Adjustments
ExpressCard 2000| Instant Issuance Card Personalization System | Hardware Service Manual
Page 150
4) Repeat the
Calibrate Wheel Home
operation several times until you see the same number three
times in a row. If the number continues to change after 10 tests, report the unit’s failure to calibrate.
5) Check that the value below
Calibrate Wheel Home
is between 4 and 10. If the value is not in that
range, report the unit’s failure to calibrate within the acceptable range.
6) After successfully calibrating, press the
Save
button to save the new embosser wheel center value.
7) Press the
OK
button to dismiss the popup window confirming it has been saved.
8) Open the top access door and inspect the embosser tine position to make sure the currently selected
tine is centered in the embosser bridge opening.
9) Press the
Status
button to return to the
Status
page.