Room layout/environment, Power supply – AT&T DEFINITY Remote Port Security Device User Manual

Page 21

Advertising
background image

Room Layout/Environment

While the location of the RPSD Lock is not critical to its function, it is best if the Lock is kept in
an equipment cabinet near the PBX modem. This helps protect the Lock against dust and other
precipitate, as well as protecting against physical damaging from being knocked to the floor or
having things dropped on it. Alternative locations are on a table near the PBX modem or on top
of the PBX cabinet. This last location is discouraged as heat tends to accumulate at the top of the
PBX cabinet.

Note:

A damaged Lock prohibits use of the RMATS channel. Secure location of the RPSD
Lock is very important to maintaining uninterrupted service.

If more than one RPSD Lock is installed at a particular customer site, the Locks may be stacked
on top of each other to save space. Very little heat is generated by the Locks, so separating them
is not warranted.

Note:

In a multiple Lock installation, be certain that you label the Locks according to which
lines they protect, to prevent confusion.

Power Supply

The RPSD Lock and the RPSD Key devices are both powered by ordinary AC outlets. These
need not be grounded (three prong) outlets. Use of extension cords where needed is acceptable.
However, given that an interruption in power to the RPSD Luck unit will result in a complete
blockage of both incoming and outgoing calls on the RMATS channel, and given that a power
outage could require administration of the PBX, it is advised that the RPSD Lock be powered
from the Uninterruptible Power Supply (UPS) that is frequently included in a PBX configuration.
Additionally, if the modem to the RMATS channel is external (System 85 and DEFINITY
Generic 2 models), the modem should also be powered from the UPS.

Note:

A locked channel is inaccessible during a power outage for the duration of the outage.
No administration of the RPSD Lock need be done when the outage ends. That is, when
power is restored, the RPSD Lock device will automatically come back on-line and
reset itself to an Idle/Locked state. Key information and parameters will be unchanged
by the outage.

Where a UPS is present, there are often many demands placed on it. The power pack for the
Lock draws a maximum of 18 watts. This should not place any great strain on the UPS, but

should be considered with the overall draw on the UPS.

External surge protection is optional.

Room Layout/Environment

2-3