Connecting the rpsd lock to the co line – AT&T DEFINITY Remote Port Security Device User Manual

Page 31

Advertising
background image

You will need the following components to install the RPSD Lock:

RPSD Lock device

the CO line assigned as the RMATS channel (on customer premises)

the PBX modem (on customer premises)

6 position wire (length depends on local configuration)

two modular connectors

two DB25 connectors (male)

RS-232 cable

administration terminal

AC outlet

RPSD Lock power pack

Connecting the RPSD Lock to the CO Line

The following components are needed to connect the RPSD Lock device to the CO line:

RPSD Lock

the CO line assigned as the RMATS channel

two modular connectors

6 position wire

RJ11 connector (for the CO line)

To connect the RPSD Lock device to the CO line, use the following procedure:

1

2

3

4

5

The customer must contact the technical support center to get the port number for the
RMATS channel.

Locate the CO line for the RMATS port where it connects to the modem.

Install an RJ11 receptacle on the CO line.

Connect a wired modular connector to the CO line.

Plug the modular connector on the other end of the wire into the

Telco

port on the back

of the RPSD Lock.

Note:

Bypass connectors are optional. See Figure 2-1.

Hardware Installation Procedures

2-13