Sc - set communications parameters – AT&T DEFINITY Remote Port Security Device User Manual

Page 73

Advertising
background image

SC - Set Communications Parameters

Syntax:

sc <speed,length_parity>

[

RETURN

]

The Set Communications Parameters command is used to set the communications link speed,
character length, and parity on the serial port. The default setting is 9600 baud, 8 bit, no parity.

In the syntax above

sc

is the command,

speed

is the link speed, and

length_parity

are the

character length and parity.

The options for

speed

and

length_parity

are:

speed - 300, 600, 1200, 2400, 4800, 9600, or 19200 baud (trailing zeros may be omitted,

meaning you may enter

sc 24

for 2400 baud)

length_parity

8N - 8 bits no parity

7N - 7 bits no parity

7E - 7 bits even parity

7O - 7 bits odd parity

If either

speed

or

length_parity

are omitted, the current entry is left unchanged.

Sample Command and Response:

> sc 1200,7E

JPLock02 005 08/17/90 15:48:21 Comms Params Changed to 1200/7E

RPSD System Administrator Command Set

3-27