Fd - force disconnect, D - date set, Fd - force disconnect d - date set – AT&T DEFINITY Remote Port Security Device User Manual

Page 71

Advertising
background image

FD - Force Disconnect

Syntax:

fd

[

RETURN

]

The Force Disconnect command disconnects a call in progress. This might be used to clear the
channel for a higher priority call. The Lock will request confirmation of a Force Disconnect
command.

If a Force Disconnect command is issued when no call is in progress, an error message will
be returned.

Sample Command and Response:

JPLock01 195 08/17/90 14:23:55

Call Received

JPLock01 196 08/17/90 14:24:04

KEY20 [#4321] Connected

> fd

Disconnect Current Call (Y/N) ? y

JPLock01 197 08/17/90

14:58:39 Force Disconnect

D - Date Set

Syntax:

d <mm/dd/yy>

[

RETURN

]

Sets the date for the RPSD Lock. This must be done in order for the System Activity Log to be

accurate. The date should be set upon installation of the Lock to be sure that it is correct.

In the above syntax,

d

is the command and

<mm/dd/yy>

is the date in month, day, and year

format. Be certain to use two digits for each part of the date, including a zero at the beginning
for months or days less than 10 (for example, 08/01/90). Only the last two digits are used for the
year. Also be certain to separate the month, day, and year with the slash (/) character.

Sample Command and Response:

> d 08/14/90

JPLock01 198 08/17/90 15:14:13 Date Changed OK

RPSD System Administrator Command Set

3-25

Advertising