Suction-piping checklist – Goulds Pumps 3796 i-FRAME - IOM User Manual

Page 31

Advertising
background image

Example: Installation for expansion

Correct

Incorrect

1

1.

Expansion loop/joint

Suction-piping checklist

Performance curve reference

Suction-piping checks

Check

Explanation/comment

Checked

Check that the distance between the inlet flange of

the pump and the closest elbow is at least five pipe

diameters.

This minimizes the risk of cavitation in

the suction inlet of the pump due to

turbulence.
See the Example sections for

illustrations.

Check that elbows in general do not have sharp

bends.

See the Example sections for

illustrations.

Check that the suction piping is one or two sizes

larger than the suction inlet of the pump.
Install an eccentric reducer between the pump inlet

and the suction piping.

The suction piping must never have a

smaller diameter than the suction inlet of

the pump.
See the Example sections for

illustrations.

Check that the eccentric reducer at the suction flange

of the pump has the following properties:
• Sloping side down
• Horizontal side at the top

See the example illustrations.

If suction strainers or suction bells are used, check

that they are at least three times the area of the

suction piping.

Suction strainers help to prevent

clogging.
Mesh holes with a minimum diameter of

1/16 in. (1.6 mm) are recommended.

If more than one pump operates from the same

liquid source, check that separate suction-piping lines

are used for each pump.

This recommendation helps you to

achieve a higher pump performance.

If necessary, make sure that the suction piping

includes a drain valve and that it is correctly installed.

Installation (Continued)

Model 3796 i-FRAME Installation, Operation, and Maintenance Manual

29

Advertising