Seal chamber and stuffing box cover inspection – Goulds Pumps 3796 i-FRAME - IOM User Manual
Page 87
Advertising
Seal chamber and stuffing box cover inspection
Checklist
Perform these checks when you inspect the seal chamber and stuffing box cover:
• Make sure that these surfaces are clean:
• Seal chamber and stuffing box cover
• Mounting
• Make sure there is no pitting or wear greater than 1/8 in. (3.2 mm) deep.
Replace the seal chamber and stuffing box cover if pitting or wear exceeds this measurement.
• Inspect the machined surfaces and mating faces noted in the figures.
These images point to the areas to inspect on the seal chambers, stuffing box covers, and backplates:
184
Figure 22: BigBore
TM
chamber
184
Figure 23: Stuffing box cover
Maintenance (Continued)
Model 3796 i-FRAME Installation, Operation, and Maintenance Manual
85