Pump-to-driver alignment instructions – Goulds Pumps 3796 i-FRAME - IOM User Manual

Page 43

Advertising
background image

a) Attach one indicator (P) so that the indicator rod comes into contact with the perimeter of the

driver coupling half (Y).
This indicator is used to measure parallel misalignment.

b) Attach the other indicator (A) so that the indicator rod comes into contact with the inner end of

the driver coupling half.
This indicator is used to measure angular misalignment.

P

A

Y

X

2. Rotate the pump coupling half (X) in order to check that the indicators are in contact with the driver

coupling half (Y) but do not bottom out.

3. Adjust the indicators if necessary.

Pump-to-driver alignment instructions

Perform angular alignment for a vertical correction

1. Set the angular alignment indicator to zero at the top-center position (12 o’clock) of the driver

coupling half (Y).

2. Rotate the indicator to the bottom-center position (6 o’clock).
3. Record the indicator reading.

When the

reading

value is...

Then...

Negative

The coupling halves are farther apart at the bottom than at the top. Perform one of

these steps:
• Add shims in order to raise the feet of the driver at the shaft end.
• Remove shims in order to lower the feet of the driver at the other end.

Positive

The coupling halves are closer at the bottom than at the top. Perform one of these

steps:
• Remove shims in order to lower the feet of the driver at the shaft end.
• Add shims in order to raise the feet of the driver at the other end.

X Y

Shims

Figure 11: Side view of an incorrect vertical alignment

4. Repeat the previous steps until the permitted reading value is achieved.

Perform angular alignment for a horizontal correction

Installation (Continued)

Model 3796 i-FRAME Installation, Operation, and Maintenance Manual

41