Pre-assembly inspections, Replacement guidelines, Placement guidelines – Goulds Pumps 3796 i-FRAME - IOM User Manual
Page 84
2. Loosen the bolts attached to the bearing-frame flange and remove the C-face adapter from the
bearing frame.
Pre-assembly inspections
Guidelines
Before you assemble the pump parts, make sure you follow these guidelines:
• Inspect the pump parts according to the information in these pre-assembly topics before you
reassemble your pump. Replace any part that does not meet the required criteria.
• Make sure that the parts are clean. Clean the pump parts in solvent in order to remove oil, grease, and
dirt.
NOTICE: Protect machined surfaces while you clean the parts. Failure to do so may result in
equipment damage.
Replacement guidelines
Casing check and replacement
Inspect the casing for cracks and excessive wear or pitting. Thoroughly clean gasket surfaces and alignment
fits in order to remove rust and debris.
Repair or replace the casing if you notice any of these conditions:
• Localized wear or grooving that is greater than 1/8 in. (3.2 mm) deep
• Pitting that is greater than 1/8 in. (3.2 mm) deep
• Irregularities in the casing-gasket seat surface
Impeller replacement
This table shows the criteria for replacing the impeller:
Impeller parts
When to replace
Impeller vanes
• When grooved deeper than 1/16 in. (1.6 mm),
or
• When worn evenly more than 1/32 in. (0.8 mm)
Pumpout vanes
When worn or bent more than 1/32 in. (0.8 mm)
Vane edges
When you see cracks, pitting, or corrosion damage
Impeller areas to inspect
101
a
b
c
c
Figure 18: Areas to inspect for wear on the 3196 impeller.
Frame adapter check and replacement
• Replace the frame adapter if it has cracks or excessive corrosion damage.
• Make sure the gasket surface is clean.
Maintenance (Continued)
82
Model 3796 i-FRAME Installation, Operation, and Maintenance Manual