Permitted indicator values for alignment checks, Cold settings for parallel vertical alignment, Alignment measurement guidelines – Goulds Pumps 3796 i-FRAME - IOM User Manual

Page 42: Attach the dial indicators for alignment

Advertising
background image

When

Why

Periodically

This follows the plant operating procedures.

Permitted indicator values for alignment checks

NOTICE: The specified permitted reading values are valid only at operating temperature. For cold
settings, other values are permitted. You must use the correct tolerances. Failure to do so can result in
misalignment and reduced pump reliability.

When dial indicators are used to check the final alignment, the pump and drive unit are correctly aligned
when these conditions are true:

• The total indicator runout is a maximum of 0.002 in. (0.05 mm) at operating temperature.
• The tolerance of the indicator is 0.0005 in./in. (0.0127 mm/mm) of indicator separation at operating

temperature.

Cold settings for parallel vertical alignment

Introduction

This section shows the recommended preliminary (cold) settings for electric motor-driven pumps based on
different temperatures of pumped fluid. Consult driver manufacturers for recommended cold settings for
other types of drivers such as steam turbines and engines.

Recommended settings for model 3796

Pump temperature

Recommended setting

50°F (10°C)

0.002 in. (0.05 mm), low

150°F (65°C)

0.001 in. (0.03 mm), high

250°F (120°C)

0.005 in. (0.12 mm), high

350°F (175°C)

0.009 in. (0.23 mm), high

450°F (218°C)

0.013 in. (0.33 mm), high

550°F (228°C)

0.017 in. (0.43 mm), high

650°F (343°C)

Not applicable

700°F (371°C)

Not applicable

Alignment measurement guidelines

Guideline

Explanation

Rotate the pump coupling half and the driver coupling half

together so that the indicator rods have contact with the same

points on the driver coupling half.

This prevents incorrect measurement.

Move or shim only the driver in order to make adjustments.

This prevents strain on the piping

installations.

Make sure that the hold-down bolts for the driver feet are tight

when you take indicator measurements.

This keeps the driver stationary since

movement causes incorrect

measurement.

Make sure that the hold-down bolts for the driver feet are loose

before you make alignment corrections.

This makes it possible to move the driver

when you make alignment corrections.

Check the alignment again after any mechanical adjustments.

This corrects any misalignments that an

adjustment may have caused.

Attach the dial indicators for alignment

You must have two dial indicators in order to complete this procedure.
1. Attach two dial indicators on the pump coupling half (X):

Installation (Continued)

40

Model 3796 i-FRAME Installation, Operation, and Maintenance Manual