Discharge piping checklist – Goulds Pumps 3796 i-FRAME - IOM User Manual

Page 33

Advertising
background image

Example: Suction piping equipment

Correct

Incorrect

1

2

3

4

5

1.

Suction pipe sloping upwards from liquid source

2.

Long-radius elbow

3.

Strainer

4.

Foot valve

5.

Eccentric reducer with a level top

1

1.

Air pocket, because the eccentric reducer is not
used and because the suction piping does not slope
gradually upward from the liquid source

Discharge piping checklist

Checklist

Check

Explanation/comment

Checked

Check that an isolation valve is

installed in the discharge line.

The isolation valve is required for:
• Priming
• Regulation of flow
• Inspection and maintenance of the pump
See Example: Discharge piping equipment for

illustrations.

Check that a check valve is installed in

the discharge line, between the

isolation valve and the pump discharge

outlet.

The location between the isolation valve and the

pump allows inspection of the check valve.
The check valve prevents damage to the pump and

seal due to the back flow through the pump, when

the drive unit is shut off. It is also used to restrain

the liquid flow.
See Example: Discharge piping equipment for

illustrations.

If increasers are used, check that they

are installed between the pump and the

check valve.

See Example: Discharge piping equipment for

illustrations.

If quick-closing valves are installed in

the system, check that cushioning

devices are used.

This protects the pump from surges and water

hammer.

Installation (Continued)

Model 3796 i-FRAME Installation, Operation, and Maintenance Manual

31