5. Remove the rotary portion of the seal from the sleeve by loosening the setscrews and sliding it off the
sleeve.
Refer to the mechanical-seal instructions for more information.
6. Remove the gland (250), the stationary portion of the seal, and the O-ring (360Q).
126
383
360Q
383
250
Remove the stuffing-box cover (3196, CV 3196, HT 3196, LF 3196, 3796)
1. Remove the gland nuts (355) and the gland (107).
2. Remove the stuffing-box-cover nuts (370H).
3. Remove the stuffing-box cover (184).
107
184
370H
355
184
370H
355
107
4. Remove the shaft sleeve (126).
Maintenance (Continued)