Goulds Pumps 3796 i-FRAME - IOM User Manual

Page 56

Advertising
background image

1

2

3

4

1.

Annular groove

2.

Pump-side end plate

3.

Driver

4.

Pump half of the coupling guard

The annular groove in the coupling guard half must fit around the end plate.

1

2

3

1.

Annular groove

2.

End plate (pump end)

3.

Guard half

4. Use a bolt, a nut, and two washers to secure the coupling guard half to the end plate. Tighten securely.

1

2

3

1.

Nut

2.

Washer

3.

Bolt

5. Put the driver half of the coupling guard in place:

a) Slightly spread the bottom apart.
b) Place the driver half of the coupling guard over the pump half of the coupling guard.

Commissioning, Startup, Operation, and Shutdown (Continued)

54

Model 3796 i-FRAME Installation, Operation, and Maintenance Manual

Advertising