Ds3 configuration, Protection configuration, Miscellaneous – ADTRAN MX2800 M13 User Manual

Page 159: Ds2 configuration

Advertising
background image

MX2800 M13 Multiplexer User Manual

Acceptance Test Procedure, Appendix A

61200290L1-1G

A-3

NOTE

To change an option, simply enter the corresponding number, press

E

NTER

,

and follow the prompts.

DS3 Configuration

Framing

= C-Bit (default = M13)

Line Length

= Use 0-225 ft. (default) or 225-450 ft., depending on the distance to the DS3 Cross

connect panel or connecting equipment.

Timing

= Local (default = Loop)

NOTE

When performing tests to a DS3 loopback, the timing must be set to

Local

to guarantee DS3 frame synchronization and error-free testing during bit
error tests. Normal operation generally requires that this attribute be set
back to

Loop

(system default) after all acceptance tests are completed.

One exception to the rule is when connecting two MX2800s together on a
back-to-back basis (DS3s facing one another). In that case, one MX2800
must be set to

Local

and the other to

Loop

.

Remote Loopbacks

= FEAC/C-Bit (default)

XCV Threshold

= Disabled (default)

Protection Configuration

Active Controller

= A (default)

• Network Protection = Disabled (default)

Max Switch Threshold

= 3 (default)

Min. Switching Period

(sec.) = 10 (default)

Miscellaneous

Loopback Time Ou

t = 5 min. (default)

DS2 Configuration

DS2 #1

= M12(4xT1)

DS2 #2

= M12(4xT1)

DS2 #3

= M12(4xT1)

DS2 #4

= M12(4xT1)

DS2 #5

= M12(4xT1)

Advertising