Connection timeout, Pause between calls, Dialout on trap – ADTRAN MX2800 M13 User Manual

Page 60: Answer on ring, Modem mode, Modem baud rate

Advertising
background image

3-20

61200290L1-1G

Section 3, Configuration

MX2800 M13 Multiplexer User Manual

Connection Timeout

The MX2800 waits for a connection for the number of seconds entered in this field. Timing begins as soon
as the dial command is issued. This field must be set for greater than 20 seconds.

Pause Between Calls

The MX2800 waits between redial attempts for the number of seconds entered in this field.

Dialout On Trap

This field is used to enable or disable the MX2800’s ability to dial out to report traps. Modem Mode
configured for VT-100 reports error conditions in plain ASCII with the following information:

• The Unit ID value programmed in the Equipment Identification portion of the System Management

screen. Refer to

System Management

on page 3-16.

• A trap code indicating the error condition

• A text description of the fault

• The date and time when the error was logged

When Modem Mode is configured for PPP or SLIP, the MX2800 logs into the PPP/SLIP host and reports
the error conditions to the hosts designated under Trap IP Addresses. Refer to

Trap IP Addresses

on

page 3-21.

Answer on Ring

This option enables or disables the MX2800’s ability to accept incoming calls. If enabled, incoming calls
are automatically answered by the MX2800, allowing remote performance of management functions.

Modem Mode

This field is used to select the Modem port function for the desired application (VT-100, PPP, or SLIP).
The Modem port, located on the rear panel of the MX2800, provides a telephone line (POTS) for connec-
tion to the internal V.34 modem. This setting applies only if the Management Port is set to Modem. Refer
to

Management Port

on page 3-17.

Modem Baud Rate

This option is used to set the maximum operating speed in bps of the Modem port:

• 1200

• 2400

• 4800

• 9600

• 19200

• 38400

Advertising