Loading default settings, Load default settings other than system management, Load system management default settings – ADTRAN MX2800 M13 User Manual

Page 79: Loading default settings -39, Table 3-7. self-test results -39, D in, Table 3-7

Advertising
background image

MX2800 M13 Multiplexer User Manual

Configuration, Section 3

61200290L1-1G

3-39

Loading Default Settings

Select

Load Default Settings

from the Utilities menu. Three options are available for loading default

settings.

Load Default Settings Other Than System Management

This option defaults all Network and T1/E1 interfaces but does not change management-related options.
Refer to

Management Options

on page 3-17 for the management-related options.

CAUTION

Loading the default settings will set the T1/E1 state of all DS1 ports to

Auto Enable

.

Load System Management Default Settings

This option defaults all management-related settings but does not default settings for Network and T1/E1
interfaces.

CAUTION

Loading the default settings will set the T1/E1 state of all DS1 ports to
Auto Enable. The User Account Management table is also reset to default.

Table 3-7. Self-Test Results

If the self test results are...

Then...

PASS

The self-test was successful and the unit is ready to use.

BAD RAM DATA
BAD RAM ADDRESS
BAD CODE CHECKSUM
BAD BOOT SECTOR
IOX PROGRAM FAILURE
AFE PROGRAM FAILURE
MODEM FAILURE
ETHERNET FAILURE
DS3 FAILURE
DSX FAILURE

Contact ADTRAN Technical Support. For more information, refer to

Appendix F, Warranty

.

CONFIGURATION CORRUPT

Select

Save Configuration

from the Configuration menu. If the condition

persists, contact ADTRAN Technical Support.