craft port by selecting

Configuration

,

Network Interface

and

Timing

from the

Main Menu

, or by ensuring

continuity to and proper provisioning of the MX2800 and connecting equipment.

At the DS1 level, the MX2800 has three Service States. They operate as follows:

• Disabled – No signal continuity exists through the MX2800, and no alarms are detected or transmitted.

• Enabled – Signal continuity and alarming are always enabled.

• Auto Enable (default) – Signal continuity and alarming exist only after a DS1 signal is detected at the

DS1 input to the MX2800. Once a signal is detected, the only way to disable alarming is to momentarily
toggle the DS1 channel to the Disable state as follows:

From the Main Menu, select

Configuration

,

T1/E1 Interface

and

T1 State

. From the

T1/E1 State

screen,

enter the DS1# in question; then disable signal continuity and alarm transmission. Repeat the process of
selecting the DS1 from the T1/E1 State screen, but this time select

Auto Enable

to once again provision the

slot/channel for service. No alarms are transmitted until a DS1 signal has been detected and removed, or an
unframed signal is detected.

8. CONFIGURING THE SYSTEM FOR TRAFFIC READINESS

After the previous tests are successfully completed and the default settings are restored, the MX2800 can
be considered ready for customer traffic. Specific provisioning of the DS3, DS1, and other options is deter-
mined by circuit orders and local practices.