Protection, Card comm, Protection -5 card comm -5 – ADTRAN MX2800 M13 User Manual

Page 89

Advertising
background image

MX2800 M13 Multiplexer User Manual

Status, Section 4

61200290L1-1G

4-5

Card A/Card B

These fields display the current state of the two controller cards. Possible states for the controller cards are
listed in

Table 4-6

.

Protection

This field lists the type of protection mode currently active. Possible states are listed in

Table 4-7

.

NOTE

For more information on the various types of Protection Modes, refer to

Section 7, Circuit and Network Redundancy

.

Card Comm

This field displays the current state of the communication link between the two controller cards.

• OK indicates that the cards are communicating
• Failure indicates that the cards are not able to communicate with each other
• If there is only one card installed, Non-Redundant is displayed

Table 4-6. Controller Card States

Condition

Description

Not Installed

No controller card is installed in this slot.

Standby

The controller card is ready to pass data but is currently acting as a backup card.

Active

The controller card is acting as the primary card.

Failure

The controller card has failed and needs to be replaced.

Table 4-7. Protection Types

Condition

Description

Network

Both controller cards are installed and everything is healthy. The unit is in full
network protection mode.

Circuit

Unit is in Circuit Protection Mode and everything is healthy,
or
unit is in network protection mode and a failure is present on the network.

None

One controller card is installed,
or
the unit is in Circuit Protection Mode, and the secondary card has failed.

Advertising