2-2

61200290L1-1G

Section 2, Installation and Operation

MX2800 M13 Multiplexer User Manual

NOTE

MIB files are available from ADTRAN in the support section of the
ADTRAN Web page at

www.adtran.com

.

4. POWER UP

The AC version of the MX2800 is provided with a 6-foot power cable terminated in a three-prong plug
which is connected to a grounded 120 VAC power receptacle.

NOTE

Power to the AC version of the MX2800 must be provided from a
grounded 120 VAC power receptacle.

The DC version of the MX2800 is provided with two 4-position modular terminal lug connectors. These
connectors simplify the initial wiring and connection or disconnection of the DC power when replacing
rackmount units.

NOTE

A 3-amp fuse is recommended for use in the fuse and alarm panel that
feeds the MX2800.

For more detailed information on power connections, refer to

Section 8

,

Power Loss Recovery

.

Once the modular connector is wired, push it firmly into one of the rear panel power connectors.

Figure

2-1

on page 2-3 and

Table 2-1

on page 2-3 illustrate the DC power connector and give definitions for the

four connector symbols.

NOTE

The chassis should be connected to an earth ground using the ground stud
located between the AC and DC power sources on the rear panel.