Power supply state, System state, Alarm – ADTRAN MX2800 M13 User Manual

Page 88: Power supply state -4, System state -4, Alarm -4

Advertising
background image

4-4

61200290L1-1G

Section 4, Status

MX2800 M13 Multiplexer User Manual

3. POWER SUPPLY STATE

This field indicates which types of power supplies are installed (AC or DC) in Card A and Card B and
gives their current state. See

Table 4-4

.

4. SYSTEM STATE

These fields display information regarding the two controller cards. The following sections describe the
system state fields in detail.

Alarm

This field displays what type (if any) of system alarm is currently recognized by the unit. The condition is
displayed until it clears up, with the exception of the Switched condition (which is cleared manually) and
the Excessive Switches (which is cleared when Protection Switch alarms counts are cleared). For more
information, refer to

Protection Switch Statistics

on page 5-14.

To clear the

Switched

condition, select Acknowledge Alarms (ACO)

or push the

ACO

button on the front

panel. For more information, refer to

ACO Buttons

on page 2-15 and

Acknowledge Alarms (ACO)

on page

4-6 in this section. Possible alarm types are listed in

Table 4-5

.

Table 4-4. Power Supply Conditions

Condition

Description

Normal

The power supply is fully operational.

Error

The controller card cannot communicate with the power supply.

Power Low

The power supply output level is abnormally low.

Power Fail

The power supply input power is lost.

Charger Fail

The battery backup charger has failed or has lost its AC input.

Battery Low

The battery backup has reached an insufficient energy level to power the unit.

Temp High

The power supply card temperature is abnormally high.

Temp Critical

The power supply card temperature is so high that it is approaching shut off.

Table 4-5. System State Alarm Types

Condition

Description

Supply Failure

A power supply card has failed.

Card Failure

A controller card is not passing data.

Excessive Switches

The Max Switching Threshold has been exceeded. Refer to

Maximum Switch

Threshold

on page 3-6.

Switched

A card switch has occurred.

Advertising