2 ground, 3 decoupling, 2 pll filter – Cirrus Logic CS485xx User Manual

Page 91: 1 analog power conditioning

Advertising
background image

9-11

Copyright 2009 Cirrus Logic, Inc.

DS734UM7

Pin Description

CS485xx Hardware User’s Manual

9.2.1.2 Ground

For two-layer circuit boards, care should be taken to have sufficient grounding between the DSP and parts in
which it will be interfacing (DACs, ADCs, S/PDIF Receivers, microcontrollers, and especially external
memory). Insufficient grounding can degrade noise margins between devices resulting in data integrity
problems.

9.2.1.3 Decoupling

It is necessary to decouple the power supply by placing capacitors directly between the power and ground of
the CS485xx. Each pair of power/ground pins (VDD1/GND1, etc.) should have its own decoupling capacitor.
The recommended procedure is to place a 0.1 uF capacitor as close as physically possible to each power
pin connected with a wide, low-inductance trace. A bulk capacitor of at least 10 uF is recommended for each
power plane.

9.2.2 PLL Filter

9.2.2.1 Analog Power Conditioning

In order to obtain the best performance from the CS485xx internal PLL, the analog power supply VDDA
must be as noise free as possible. A ferrite bead and two capacitors should be used to filter the VDDIO to
generate VDDA. This power scheme is shown in the Typical Connection diagrams.

Table 9-3. Core and I/O Ground Pins

LQFP-48

Pin #

Pin Name

Pin Type

Pin Description

4

GND1

Input

Core Ground.

9

GND2

22

GND3

33

GND4

7

GNDIO1

I/O Ground

19

GNDIO2

30

GNDIO3

40

GNDIO4

Table 9-4. PLL Supply Pins

LQFP-48

Pin #

Pin Name

Pin Type

Pin Description

48

VDDA

Input

PLL supply. This voltage must be 3.3V. This
must be clean, noise-free analog power.

46

GNDA

Input

PLL ground. This ground should be as noise-
free as possible.

Advertising