CS4953xx Hardware User’s Manual

Table 2-9

is a quick reference showing the different boot commands understood by the CS4953xx, in

mnemonic and actual hex value, used in CS4953xx boot sequences.

2.4 Master Boot Procedure

Note: Master Boot is currently not supported in the O/S

A master boot sequence is initiated immediately after the rising edge of RESET. The location of the
overlay to boot is outlined in

Table 2-1

. Once the rising edge of RESET has occurred, the CS4953xx will

load a single overlay from address 0x0. It should be noted that the loaded overlay must reconfigure one of
the control ports to be slave to the bus for a system host controller to configure the part. Thus, this type of
boot process will be useful in systems without a system host controller or with a simple controller that only
performs a monitoring task. Currently this mode is not used for any applications.

Figure 2-4. Master Boot Sequence Flowchart

Table 2-9. Boot Command Messages for CS4953xx

MNEMONIC

VALUE

DETAILED TABLE

SLAVE_BOOT

0x8000 0000

Table 2-2

HCMB_PARALLEL

0xE0== ====

Table 2-3

HCMB_I

2

C

0xC0== ====

Table 2-4

HCMB_SPI

0xD=== ====

Table 2-5

SOFT_RESET

0x40 00 00 00

Table 2-7

Start

RESET (Low)

RESET (High)

Done

Set HS[4:0] Pins For

Operational Mode