Switching characteristics, Cs5376a – Cirrus Logic CS5376A User Manual
Page 15
Advertising

CS5376A
DS612F4
15
SWITCHING CHARACTERISTICS
SPI 1 Interface Timing (External Master)
Parameter
Symbol Min Typ
Max
Unit
MOSI Write Timing
SSI Enable to Valid Latch Clock
t
1
60
-
-
ns
Data Set-up Time Prior to SCK1 Rising
t
2
60
-
-
ns
Data Hold Time After SCK1 Rising
t
3
120
-
-
ns
SCK1 High Time
t
4
120
-
-
ns
SCK1 Low Time
t
5
120
-
-
ns
SCK1 Falling Prior to SSI Disable
t
6
60
-
-
ns
MISO Read Timing
SCK1 Falling to New Data Bit
t
7
-
-
60
ns
SCK1 High Time
t
8
120
-
-
ns
SCK1 Low Time
t
9
120
-
-
ns
SSI Rising to MISO Hi-Z
t
10
-
-
150
ns
Figure 4. MOSI Write Timing in SPI Slave Mode
SS I
MOSI
SCLK
MSB
MSB - 1
LSB
t
6
t
5
t
4
t
3
t
2
t
1
SCK1
Figure 5. MISO Read Timing in SPI Slave Mode
MISO
SCLK
MSB
MSB - 1
LSB
t
10
t
9
t
8
t
7
SS I
SCK1
Advertising