Characteristics and specifications, Specified operating conditions, Absolute maximum ratings – Cirrus Logic CS8420 User Manual

Page 6

Advertising
background image

6

DS245F4

CS8420

1.

CHARACTERISTICS AND SPECIFICATIONS

All Min/Max characteristics and specifications are guaranteed over the Specified Operating Conditions. Typical
performance characteristics and specifications are derived from measurements taken at nominal supply voltages
and T

A

= 25°C.

SPECIFIED OPERATING CONDITIONS

AGND, DGND = 0 V, all voltages with respect to 0 V.

ABSOLUTE MAXIMUM RATINGS

AGND, DGND = 0 V; all voltages with respect to 0 V. Operation beyond these limits may result in permanent dam-
age to the device. Normal operation is not guaranteed at these extremes.

Notes:

1.

Transient currents of up to 100 mA will not cause SCR latch-up.

Parameter

Symbol Min

Typ

Max

Units

Power Supply Voltage

VD+, VA+

4.75

5.0

5.25

V

Ambient Operating Temperature:

Commercial Grade

Automotive Grade

T

A

-10
-40

-
-

+70
+85

°C
°C

Parameter

Symbol

Min

Max

Units

Power Supply Voltage

VD+, VA+

-

6.0

V

Input Current, Any Pin Except Supplies, RXP/RXN

(Note 1)

I

in

-

±10

mA

Input Voltage

V

in

-0.3

(VD+) + 0.3

V

Ambient Operating Temperature (power applied)

T

A

-55

125

°C

Storage Temperature

T

stg

-65

150

°C

Advertising