background image

Chapter 10 Adjustment

BES-962BC • BES-1262BC

233

1.

Dismount the pulley cover and turn the pulley B

q

until the pulley scale indicates 180˚ and

the needle bar is set at the lowest position. (The pulley B " " mark and the stop mark " "
are aligned.)

2.

Insert the positioning bar

w

into the hole of the pulley B

q

and fix the drive shaft.

Note) Turn the pulley B securely in the clockwise direction to eliminate a backlash.

3.

Loosen Needle bar guide bracket set screw

e

and the bolt

u

of the top dead center stopper

t

when the needle tip is positioned 10.8 mm above the center of the rotary hook shaft.

Adjust the position of the needle bar thread guide so that the set screw

r

on it is turned to

the right by 25 ~ 30˚. Tighten Needle bar guide bracket set screw

e

securely.

Note) When tightening the needle bar clamp set screw

e

, the hole in the needle bar guide should face the front.

4.

After adjustment is finished, remove the positioning bar

w

.

5.

Set the needle bar at the highest position (where the pulley B indication mark " " and the
cover indication mark " " are aligned). Lightly press the top dead center stopper

t

toward

the cushion rubber

y

, and tighten Socket head bolt for top dead center stopper

u

while

pressing down the needle bar clamp so that it faces the front. (Tightening torque: 0.78 N.m)

Note) • Make sure that the top dead center stopper does not hit the needle bar guide rail

i

at this time.