BES-962BC • BES-1262BC

258

Chapter 12 Troubleshooting

Symptom

Measures

Thread trimming motor zero point

error occurs.

• Is lint clogged between the travelling blades?

Remove it.

• Is the thread trimming motor operating?

If so, refer to the block diagram showing the cable connections and

check to see if connection from the thread breakage sensor to the main

PCB is proper. Also adjust the thread breakage sensor PCB. (Refer to

"Replacing thread breakage sensor PCB.)

• If it is not operating, refer to the block diagram showing the cable

connections and check to see if connection from the thread trimming

motor to the main PCB is proper.

• Check to see if connection from connector P3 of the main PCB to

connector P9 of the power supply PCB in the control box is proper.

• Check fuse F6 on the power supply PCB in the control box.

If it is blown, replace it with a new one. If it is blown again, replace

the power supply PCB.

Power frequency error occurs.

• Check to see if connection from connector P16 of the main PCB to

connector P10 of the power supply PCB in the control box is proper.

• Refer to the block diagram showing the cable connection and check to

see if connection from connector P26 of the power PCB in the control

box to connector P7 of the power supply PCB in the power supply base

is proper.

• Check fuse F3 on the power supply PCB in the power supply base.

If it is blown, replace it with a new one. If it is blown again, there is

a fault somewhere in the 24v system circuit.

Wiper out error occurs.

• Does the wiper on the error head remain projected?

If the wiper is tangled with a thread, remove it. If the wiper does not

return smoothly, adjust it.

• Enter the solenoid test mode and operate the wiper solenoid. Check the

icon on the panel.

If a sensor signal is not given, check to see if connection from the

wiper sensor to the head PCB is proper. Replace the wiper sensor

with a new one. Replace the head PCB with a new one.

• Is the red LED for the BC PCB off?

If not, refer to the block diagram showing the cable connections and

check to see if the connection from the BC PCB to the main PCB is

proper.

• Check to see if connection from the lower shaft motor to the BC PCB of

the bed on BC PCB whose red LED is off is proper.

Replace the harness or the lower shaft module if a short circuit

occurs due to line insertion.

• Measure the resistance values of pin 1 and pin 2, pin 2 and pin 3, pin 3

and pin 4, pin 4 and pin 5, and pin 5 and pin 1 at the connector of the

lower shaft motor with the tester and check to see if they are

approximately 2.6

.

Replace the faulty lower shaft module with a new one.

• Replace the BC PCB with a new one.

Lower shaft motor overcurrent error