3 preparation of needle bar case – Brother BES-962BC User Manual
Page 32
Chapter 2 Preparation of Embroidery Machine
BES-962BC • BES-1262BC
30
2-3 Preparation of Needle Bar Case
BES-962BC
1.
Loosen the bolt
q
and set screw
o
, and move the needle case
w
to the left.
2.
Press the change bracket collar
r
against the change case base
e
on the light, while pressing
the change bracket collar
t
against the change case base
y
on the left, and tighten the bolt
q
and set screw
!0
. Check that needles at needle bar No.1 and 9 are inserted into the needle
plate holes smoothly.
Notes)
• Check that the connecting shaft
u
does not have backlash in the horizontal direction.
• Never loose the bolt
i
of the change bracket coller
r
. If this bolt is loosened, the change bracket
coller
r
will be dislocated and the position of the needle bar case
w
will need to be adjusted.
r
q
u
w
e
t
y
i
o