Lukas P 650 Series User Manual

Page 32

Advertising
background image

32

On units with a combustion engine, you should drain the fuel from the tank and disconnect
and/or remove the starter battery.
Avoid storing the hydraulic units in a damp environment.
Please observe the regulations in the separate operating instructions for the hose lines.

Once work has been completed, all connected equipment is to be reset to its base position
before the unit is shut down. You can now stop or switch off the motor/engine on the unit and
disconnect it from the mains supply, if using an electric motor.

9. Removing the device / deactivation following operation

CAUTION!
Depending on the size and the weight of the hydraulic unit, it should be transported
to the storage site by one person or several people.

Mono-couplings:
If the connected hose lines have to be dismantled during shut-down, decouple the mono-
couplings as described in chapter "Connection of the hose lines". Ensure that you replace
the dust protection caps onto the mono-coupling halves.
Give the hydraulic unit a general clean before placing in storage. If you intend to store
the unit for longer, clean the outside thoroughly and lubricate all mechanical moving parts.

ATTENTION when using units with a combustion engine!
Check that the engine switch is set to "OFF" and remains in that position to
prevent anyone from starting the unit unintentionally!

NOTE:
If your unit is equipped with a hose reel, the hoses must be rolled onto the reels
correctly!