Lukas P 650 Series User Manual

Page 45

Advertising
background image

45

3. Loosen the union nuts on the hose lines and remove the coupling.

CAUTION!
As the case may be, make sure that port 'T' / 'T1' of the hose reel is always
connected to port 'T' of the mono-coupling.

4.

Position the new coupling and tighten the union nuts on the hose lines to a torque of

M

A

= 40 Nm and push the cover back over the couplings.

Procedure for couplings on hose pairs:

1. First of all, empty the hydraulic reservoir as described in the chapter "Replacing the

hydraulic

À uid".

2. Pull the cover back from the couplings.

5. The hydraulic

À uid reservoir must then be ¿ lled and the unit vented.

Advertising