Lukas P 650 Series User Manual
Page 55
55
1)
HP
=
High pressure
2)
LP = Low pressure
3)
1MPa = 10 bar
13.1.3 Type series P 650 4E and P 650 4E - DHR
Device type
P 650 4E
P 650 4E - DHR
Ref. number
81-53-54 (175780000) 81-53-24 (175782000)
Motor type
400V / 50 Hz ; Electric motor
Power
[kW]
3,5
[HP]
4.7
Speed
[min
-1
]
2980
[rpm.]
Max. operating
pressure
(HP)
1)
[MPa]
3)
70
[psi.]
10000
Max. operating
pressure
(LP)
2)
[MPa]
3)
14
[psi.]
2000
Flow rate
(HP)
1)
[l/min]
4 x 0,6 / turbo 2 x 1,2
[gal.-US/min]
4 x 0.13 / turbo 2 x 0.32
Flow rate
(LP)
2)
[l/min]
4 x 2,2 / turbo 2 x 4,3
[gal.-US/min]
4 x 0.48 / turbo 2 x 0.95
Max. fi ll quantity
Hydraulic fl uid
[l]
5,5
[gal.-US]
1,45
Max. usable
quantity
Hydraulic fl uid
[l]
4,8
[gal.-US]
1.27
Weight (incl. 4,3l
hydraulic fl uid)
[kg]
48,0
91
[lbs.]
106
201
Starting current
[A]
34
Valve typ
4POWER
Hose reel
NO
YES
Max. number of device
connections
4
Additional series equipment
-
Carrying handles
Toolholder