Lukas P 650 Series User Manual

Page 49

Advertising
background image

49

Trouble

Check

Cause

Solution

Connected rescue
device does not
reach its

¿ nal

position

Check hydraulic
À uid volume
in hydraulic
reservoir

Insuf

¿ cient À uid in the

hydraulic reservoir

Top up hydraulic

À uid to

the maximum

¿ lling level

Caution! Before
topping up the rescue
equipment, return to
the base position!

Usable hydraulic

À uid

volume of the unit is
insuf

¿ cient

Use a different rescue
device with a required
quantity below the
maximum usable
quantity of the unit

Connected rescue
device does not
reach its speci

¿ c

performance data

Maximum permitted
operating pressure
of the pump is not
reached

Have the pressure
limiting valve reset or
repaired by authorised
dealer or directly by
LUKAS

Defective pump block

Have repaired by
authorised dealer or
directly by LUKAS

Connected device is
defective

For the solution,
consult the operating
instructions for the
connected device

During the
functional check:
A pressure gauge
installed between
the rescue
equipment and
the hydraulic
power pack does
not indicate
the maximum
operating pressure
of the equipment.

Check the details
of the rescue
device

The operating pressure
of the connected
rescue device is
locked internally

No repair or fault
recti

¿ cation required

Connected rescue
device is defective

Consult the separate
operating manual for
the connected rescue
device

Hydraulic unit
defective

Have repaired by
authorised dealer or
directly by LUKAS